石油炼制与化工 ›› 2026, Vol. 57 ›› Issue (11): 99-106.

• 催化剂 • 上一篇    下一篇

CO2体系低温多功能脱硫剂的开发及工业应用

朱军利1,2,谢小莉1,李梦婕1,艾浩辰1,黄伟1,强涛涛2   

  1. 1. 西安元创化工科技股份有限公司
    2. 陕西科技大学轻工科学与工程学院
  • 收稿日期:2026-05-07 修回日期:2026-07-29 出版日期:2026-11-12 发布日期:2026-10-19
  • 通讯作者: 谢小莉 E-mail:250193924@qq.com
  • 基金资助:
    陕西延长石油集团科技计划项目

DEVELOPMENT AND COMMERCIAL APPLICATION OF LOW-TEMPERATURE MULTIFUNCTIONAL DESULFURIZERS FOR CO2 SYSTEMS

  • Received:2026-05-07 Revised:2026-07-29 Online:2026-11-12 Published:2026-10-19

摘要: 针对高浓度CO2原料气中H2S、COS、硫醇多组分硫化物难以深度脱除、CO2竞争吸附干扰、传统脱硫工艺冗长等问题,以煤质活性炭为载体,分步浸渍负载Fe-Ce双活性金属及K2CO3助剂,制得低温多功能复合脱硫剂3%Fe2O3-1%CeO2-5%K2CO3/活性炭。性能评价结果表明:该复合脱硫剂具有较强的抗CO2竞争吸附能力,最佳脱硫温度为50~100 ℃,在该温度下可实现H2S、COS、硫醇的高效同步脱除,3种硫化物的脱除率均达99.6%以上,出口尾气中其质量浓度均小于0.02 mg/m3;高硫含量CO2气体的穿透硫容(质量分数)达25%以上,脱硫产物以单质硫和硫酸为主;其脱硫反应过程通过持续氧化脱除H2S打破COS水解平衡、提升COS脱除效率,破除了CO2对COS水解的抑制作用。工业CO2气体脱硫应用结果表明,常温下该复合脱硫剂可稳定运行,反应器出口尾气的硫化物质量浓度在0.02 mg/m3以下,适用于工业CO2气体、合成气、液化气的低温精脱硫过程。

关键词: 多功能脱硫剂, COS水解, H2S氧化, 硫容, 脱硫精度

Abstract: To tackle the challenges including difficult deep removal of multi-component sulfides (H2S, COS and mercaptans), competitive adsorption interference of CO2, and cumbersome traditional desulfurization processes in high-concentration CO2 feed gas, a low-temperature multifunctional composite desulfurizer, 3%Fe2O3-1%CeO2-5%K2CO3/activated carbon, was prepared via stepwise impregnation of Fe-Ce bimetallic active components and K2CO3 promoter onto a coal-based activated carbon support. Performance evaluation results reveal that the composite desulfurizer possesses strong resistance against competitive CO2 adsorption. The optimal desulfurization temperature ranges from 50 to 100 °C,where efficient simultaneous removal of H2S, COS and mercaptans can be achieved, with the removal efficiency of all three sulfur compounds exceeding 99.6%, and their mass concentrations in the effluent gas is below 0.02 mg/m3. The breakthrough sulfur capacity (mass fraction) for high-sulfur content CO2 gas reaches over 25%, and the desulfurization products mainly consist of elemental sulfur and sulfuric acid. During the desulfurization reaction, continuous oxidative removal of H2S shifts the COS hydrolysis equilibrium forward and improves COS removal efficiency, which eliminates the inhibitory effect of CO2 on COS hydrolysis. Industrial application results for CO2 gas desulfurization demonstrate that the composite desulfurizer can operate stably at ambient temperature, and the mass concentration of sulfur species in the reactor outletremains below 0.02 mg/m3. It is suitable for low-temperature fine desulfurization of industrial CO2 gas, syngas and liquefied petroleum gas.

Key words: multifunctional desulfurizing agent, COS hydrolysis, H2S oxidation, sulfur capacity, desulfurization accuracy