石油炼制与化工 ›› 2026, Vol. 57 ›› Issue (12): 92-99.

• 控制与优化 • 上一篇    下一篇

阀门故障对PX吸附分离性能影响的模拟研究

杨彦强,王德华,朱宁,王辉国   

  1. 中石化石油化工科学研究院有限公司
  • 收稿日期:2026-06-22 修回日期:2026-08-17 出版日期:2026-12-12 发布日期:2026-11-17
  • 通讯作者: 王辉国 E-mail:wanghg.ripp@sinopec.com

SIMULATION STUDY ON THE INFLUENCE OF VALVE FAILURES ON THE PERFORMANCE OF PARA-XYLENE ADSORPTIVE SEPARATION PROCESS


  • Received:2026-06-22 Revised:2026-08-17 Online:2026-12-12 Published:2026-11-17

摘要: 基于前期研究建立的模拟移动床吸附分离过程模型,模拟研究了多阀式SMB吸附塔物流阀门故障对对二甲苯(PX)吸附分离性能的影响。结果表明:在两塔24床层的PX吸附分离工艺中,对阀门故障采用保持容错或下移容错处理方式,任意一台阀门发生故障对PX纯度的影响幅度不超过0.01%,对PX收率的影响幅度不超过0.2%;两个连续床层相同物流阀门故障对PX纯度和收率的影响更加明显。解吸剂和原料油的阀门故障宜采取下移容错方式,而抽出液和抽余液的阀门故障宜采取保持容错方式;采用适宜的容错方式处理时,任意1~2台阀门故障对PX吸附分离性能均没有明显影响;某一床层或多床层全部阀门发生故障时,PX纯度提升而PX收率下降;随着发生故障床层阀门数量增加,PX纯度提升幅度和PX收率降低幅度整体呈增大趋势。

关键词: 模拟移动床, 对二甲苯, 阀门故障, 模拟研究

Abstract: Based on the established model of simulated moving bed adsorptive separation process from previous researches, the influence of switching-valve failures on the adsorption performance for para-xylene (PX) was investigated via simulation calculation. The results indicate that, in the PX adsorption and separation process with 24 adsorbent beds, either adopting the maintenance fault-tolerant mode or shift-down fault-tolerant mode, the impact of any valve failure on PX purity does not exceed 0.01%, and 0.2% on PX recovery. When identical stream valves of two consecutive beds malfunction, the impacts on PX purity and recovery become more significant. It is advisable for desorbent and feed flow valves to adopt a shift-down fault-tolerant mode, and for extract and raffinate flow valves to adopt a maintenance fault-tolerant mode. When adopting the appropriate fault-tolerant mode, the failures of any one or two valves have little effect on the adsorptive separation for PX. When all the valve failures happen in one or multiple adsorbent beds, the purity of PX increases and the recovery decreases. With an increasing number of valve failures, the magnitude of PX purity improvement and PX recovery loss exhibits an overall increasing trend.

Key words: simulated moving bed, para-xylene, valve failure, simulation study