石油炼制与化工

• 分析与评定 • 上一篇    

等量电位滴定法测定炼油厂高硫污水中氯化物

陆克平   

  1. 中国石化安庆分公司检验中心
  • 收稿日期:2008-07-22 修回日期:1900-01-01 出版日期:2008-12-12 发布日期:2008-12-12
  • 通讯作者: 陆克平

DETERMINATION OF CHLORIDE CONTENT IN REFINING WASTEWATER WITH HIGH SULFUR CONTENT BY POTENTIOMETRIC METHOD

  • Received:2008-07-22 Revised:1900-01-01 Online:2008-12-12 Published:2008-12-12

摘要: 针对现行硝酸汞容量法测定安庆分公司部分炼油污水中氯离子含量出现偏高和终点变色迟缓、返色等现象,通过改进污水预处理方式,改用银量法等量电位滴定替代手工指示剂硝酸汞容量法测定氯离子含量,氯离子回收率为99.0%~102.0%,检测最低浓度为1.8×10-5 mol/L,测定结果与离子色谱法测定结果基本一致,该方法适合炼油装置废水中氯离子的分析。

关键词: 硝酸银, 电位滴定, 预处理, 污水, 氯化物

Abstract: When measuring the chloride content of refining wastewater at SINOPEC Anqing Company using volumetric determination with mercury nitrate, end point error seemed to affect the accuracy of test results. Measures, such as improving wastewater sample pretreatment and using potentiometric titration with silver nitrate to replace manual indicator method, were adopted. Since then the recovery rate of Cl- ions reached 99.0%~102.0%, the minimum detection limit was 1.8×10-5 mol/L and the test results of this method were in good agreement with the results of determination by ion chromatography. This method is suitable for determining chloride content of wastewater in refinery and also other concerning environmental wastewater.

Key words: silver Nitrate, potentiometric titration, pretreatment, wastewater, chloride