THE HYDROGENATION UPGRADING INDUSTRIAL TEST TO PRODUCE LUBE AND WAX FROM F-T WAXES

  

  • Received:2015-10-16 Revised:2015-12-07 Online:2016-06-12 Published:2016-06-02

Abstract:

The hydrogenation upgrading industrial test of F-T wax was carried out in Nangyang wax fine chemical plant in order to manufacture high quality lube oil base stock and special wax. The industrial test uses F-T wax manufactured by Zhenhai Refining & Chemnical Company as raw materials. Practice shows that it can manufacture pour point less than -30 ℃, viscosity index more than 140 lube oil base stock and special wax with high melting point by reasonable start up method and operating parameters.

Key words: F-T wax, hydroupgrading, base oil, commercial application