NUMERICAL SIMULATION AND STRUCTURE OPTIMIZATION OF UOC TYPE QUENCH BOX

  

  1.  
  • Received:2018-04-24 Revised:2018-06-22 Online:2019-01-12 Published:2019-01-29
  • Contact: Lanyi Sun E-mail:sunlanyi@163.com
  • Supported by:
     

Abstract: Based on literature experimental data, the numerical model validation was performed and the accuracy of the selected numerical model was verified. Based on industrial operating conditions, Fluent software was used to simulate the hydrodynamic performance of UOC quench box. The structure optimization of the spacing of contractive-type flow passages and the distance between the screen hole baffle and the square box was conducted. In addition, the baffle was added at the exit of contractive-type flow passage. The results showed that the performance of the optimized quench box is better than that of the basic configuration. The temperature distribution unevenness is reduced by 36.8% and the pressure drop is reduced by 21 Pa. The comprehensive performance of the quench box is greatly improved.

Key words: quench box, numerical simulation, structure optimization, temperature distribution unevenness