PETROLEUM PROCESSING AND PETROCHEMICALS ›› 2021, Vol. 52 ›› Issue (3): 21-23.

Previous Articles     Next Articles

STUDY ON REAL-TIME MEASURING METHOD FOR CATALYST/OIL RATIO IN FCCU RISER

  

  • Received:2020-08-06 Revised:2020-09-15 Online:2021-03-12 Published:2021-03-01

Abstract: The catalyst/oil ratio in the riser of FCCU has an important influence on the reaction depth. It is necessary to monitor and regulate the catalyst/oil ratio in real-time. A real-time measuring method for catalyst/oil ratio in the riser of FCCU was proposed based on the relationship between pressure drop and particle mass flow rate in the T-bend at exit of the riser. The results indicated that the method is feasible and the measured data is credible.

Key words: FCCU, riser, T-bend, catalyst/oil ratio, particle flow rate