Petroleum Processing and Petrochemicals ›› 2019, Vol. 50 ›› Issue (11): 21-25.

Previous Articles     Next Articles

INDUSTRIAL APPLICATION OF JR-SA06 EFFICIENT SLURRY DEASH AGENT

    

  1.  
  • Received:2019-03-07 Revised:2019-06-13 Online:2019-11-12 Published:2019-11-29
  • Supported by:
     

Abstract: The removal of solid catalyst powder from FCC slurry is a common technical challenge in the deep processing of FCC slurry. To realize deep purification for slurry and to improve the comprehensive utilization value of the slurry, the JR-SA06 efficient slurry deash agent was first applied in 2.3 Mt/a FCC unit of a company. The application results demonstrated that adding 500 μg/g deash agent based on the FCC slurry and settling at 90-95 ℃ for 72 hours, the ash content in the slurry decreased from 0.28% to 0.019%, removal rate of ash reached 93.16%, which is superior to the common deash agents and creates good conditions for the subsequent processing and utilization of slurry.

Key words: catalytic cracking, slurry, deash agent, ash, removal rate

CLC Number: