  • Received:2010-11-22 Revised:2011-01-11 Online:2011-06-12 Published:2011-06-12

摘要: 采用Photo/Fenton/C2O42-体系处理含酚炼油废水,研究了反应机理,建立了Photo/Fenton/C2O42-体系降解苯酚的动力学方程。实验研究结果表明,光助Fenton技术能有效地提高Fenton试剂的降解效率,在H2O2溶液投加量为0.5 mL、反应温度40 ℃、草酸钠投加量10mL、FeSO4·7H2O投加量为0.05g、pH值为3,反应时间为30 min的条件下,苯酚的降解率可达到98%以上。实验结果同时证明了含酚炼油废水的Photo/Fenton/C2O42-氧化反应属于一级反应。

关键词: Fenton试剂, 可见光, 草酸盐, 含酚炼油废水

Abstract: In this paper refining wastewater containing phenol was disposed by photo/Fenton/ C2O42- system, the reaction mechanism was discussed and a kinetic equation was set up. The experimental results indicated that photo/Fenton/ C2O42- technology could enhance the removal of phenol by Fenton reagent effectively. When treating 250 mL of wastewater containing 500 mg/L phenol under the conditions of a H2O2 (30%) dosage of 0.5 mL,a Na2C2O4 (1 g/L) dosage of 10 mL, a FeSO4·7H2O dosage of 0.05 g, a pH value of 3, a reaction temperature of 40℃ and a reaction time of 30 min, the phenol removal rate reached more than 98%. And the experimental results indicated that the oxidizing reaction of wastewater containing phenol by Photo/Fenton/C2O42- technology was a first order reaction.

Key words: Fenton reagent, visible light, oxalate, refining wastewater containing phenol