石油炼制与化工

• 节能减排 • 上一篇    下一篇

深度处理污水在循环冷却水系统回用的研究

杜海军1,吴雪梅2,张凡华2,罗旭3   

  1. 1. 乌鲁木齐石化公司西峰集团博达公司
    2. 乌鲁木齐石化公司化肥厂
    3. 乌鲁木齐石化研究院
  • 收稿日期:2010-11-09 修回日期:2011-02-14 出版日期:2011-08-12 发布日期:2011-08-12
  • 通讯作者: 杜海军

RESEARCH ON THE RECYCLE OF ADVANCED TREATED WASTEWATER IN CIRCULATING COOLING WATER SYSTEM

  • Received:2010-11-09 Revised:2011-02-14 Online:2011-08-12 Published:2011-08-12

摘要: 在循环冷却水系统回用了深度处理污水作补充水后,导致监测到的腐蚀率大幅升高,甚至超过了石化行业标准的上限值。针对循环水的腐蚀性急剧加重的问题,分析了各种影响因素,发现主要原因是回用水引起水质恶化,使原有的缓蚀阻垢剂不能起到足够的缓蚀作用。改进缓蚀阻垢剂的配方后,循环冷却水的监测腐蚀率明显降低,且远小于石化行业标准的上限值。

关键词: 深度处理污水, 循环冷却水系统, 腐蚀, 缓蚀阻垢剂, 配方优化

Abstract: After recycling advanced treated wastewater into the circulating cooling water system, the corrosion rate of the monitoring carbon steel strip increased significantly, sometimes it even exceeded the upper limit of the standard set by petrochemical industry. To solve this serious corrosion problem, factors affecting this corrosion system were analyzed and it was concluded that the corrosion and scale inhibitor in the system could not work effectively due to the degradation of water quality by using advanced treated wastewater as make up water. Through optimizing the formula of corrosion and scale inhibitor, a modified inhibitor replaced the former one and the corrosion problem was solved successfully.

Key words: advanced treated wastewater, circulating cooling water system, corrosion, corrosion and scale inhibitor, formula optimization