石油炼制与化工 ›› 2023, Vol. 54 ›› Issue (12): 127-134.

• 设备及防腐 • 上一篇    下一篇

静电吸附净油反应器的设计优化及应用性能

石荣雪1,刘克成1,张立军1,孙东平2,王浩然2,孙墨杰2   

  1. 1. 国网河北省电力有限公司电力科学研究院
    2. 东北电力大学化学工程学院
  • 收稿日期:2023-03-17 修回日期:2023-08-14 出版日期:2023-12-12 发布日期:2023-12-05
  • 通讯作者: 石荣雪 E-mail:srxdyx1234@163.com
  • 基金资助:
    绝缘油深度净化方法及回用技术升级

DESIGN OPTIMIZATION AND APPLICATION PERFORMANCE OF ELECTROSTATIC ADSORPTIVE OIL PURIFICATION REACTOR

  • Received:2023-03-17 Revised:2023-08-14 Online:2023-12-12 Published:2023-12-05

摘要: 针对变压器油运行过程中受外界因素影响而老化导致性能下降的问题,基于静电吸附原理,利用Ansoft Maxwell有限元仿真软件对“波浪”形曲面极板构造梯度非均匀电场,对变压器油中电中性杂质和带电杂质在梯度非均匀电场中的运动规律及模式进行了探究,进而研制了静电吸附净油反应器;在此基础上,设计了正交试验方案以检验该静电吸附净油反应器对油品品质的提升效果,并优化了净油反应器的工作条件。结果表明,该静电吸附净油反应器的最优工作条件为:电压12 kV、温度45 ℃、流速0.1 m/s;经该反应器净化处理后,变压器油的介质损耗因数由0.042 58降至0.003 76,说明研制的净油反应器可有效提升老化变压器油的品质。

关键词: 静电吸附, 梯度非均匀电场, 变压器油, 介电损耗因数

Abstract: In order to solve the problem of performance degradation of transformer oil due to external factors during operation, based on the principle of electrostatic adsorption, Ansoft Maxwell finite element simulation software was used to construct gradient non-uniform electric field on the "wave"-type curved pole plate. The movement law and pattern of electrically neutral impurities and charged impurities in the gradient non-uniform field in the transformer oil was investigated. On this basis, an orthogonal test scheme was designed to test the effect of the electrostatic adsorption reactor on oil quality, and the working conditions of the oil purification reactor were optimized. The results showed that the optimum working conditions of the electrostatic adsorption reactor were as follows: voltage 12 kV, temperature 45 ℃, flow rate 0.10 m/s. After purification treatment by the reactor, the dielectric loss factor of transformer oil reduced from 0.042 58 to 0.003 76, which indicated that the developed oil purification reactor could effectively improve the quality of aging transformer oil

Key words: electrostatic adsorption, non-uniform electric field, transformer oil, dielectric loss factor