石油炼制与化工 ›› 2025, Vol. 56 ›› Issue (1): 86-91.

• 基础研究 • 上一篇    下一篇

高压气瓶连续放氢过程影响因素研究

王云峰1,吕炎峰2,王哲1,曹文红2,郭晓璐1   

  1. 1. 合肥通用机械研究院有限公司
    2. 浙江蓝能氢能科技股份有限公司
  • 收稿日期:2024-03-25 修回日期:2024-09-10 出版日期:2025-01-12 发布日期:2024-12-27
  • 通讯作者: 王云峰 E-mail:2356705436@qq.com
  • 基金资助:
    国家重点研发计划

STUDY ON INFLUENCING FACTORS DURING CONTINUOUS HYDROGEN DISCHARGE OF HIGH-PRESSURE CYLINDERS

#br#   

  • Received:2024-03-25 Revised:2024-09-10 Online:2025-01-12 Published:2024-12-27

摘要: 通过建立高压气瓶数值模型,考察放氢初始温度、放氢时间、放氢方式和放氢余压对气瓶连续缓慢放氢过程瓶内最低温度的影响。模拟结果表明,温度控制是连续放氢过程的重点,适当提高初始温度和增加放氢时间可有效提高瓶内最低温度。相比于先慢后快放氢和阶段式放氢,放氢过程应优先选用先快后慢放氢和线性放氢方式,这两种放氢方式在瓶内最低温度和氢气流量控制方面均取得良好效果。提高放氢余压也可提高放氢结束时瓶内最低温度,但提高放氢余压在一定程度上减少了放氢质量,除特殊要求或场景外不建议将放氢余压设定过高。

关键词: 高压气瓶, 放氢, 数值模拟

Abstract: The effects of different initial temperature, time, method and residual pressure on the minimum temperature during continuous slow hydrogenation discharge were investigated by establishing a numerical model of high-pressure gas cylinder. The results showed that temperature control is the key point of continuous hydrogenation discharge process, and the minimum temperature in the gas cylinder can be effectively controlled by appropriately increasing the initial temperature and the time of hydrogenation discharge. Compared with the first slow then fast and the stage method of hydrogenation discharge, the first fast then slow and linear method should be preferred in the hydrogenation discharge process, and these two methods have achieved good results in the minimum temperature and the control of hydrogen flow in the gas cylinder. Increasing the residual pressure of hydrogenation discharge can also increase the minimum temperature in the gas cylinderat the end of hydrogenation discharge, but reduce the quality of hydrogenation discharge to a certain extent. It is not recommended to set the residual pressure of hydrogenation discharge too high except for special requirements or scenarios.

Key words: high-pressure gas cylinder, hydrogen discharge, numerical simulation