石油炼制与化工 ›› 2026, Vol. 57 ›› Issue (12): 110-115.

• 节能减排 • 上一篇    下一篇

炼化污水厂反渗透系统微生物污染诊断与处理

王金鑫   

  1. 中国石化镇海炼化有限公司
  • 收稿日期:2026-06-15 修回日期:2026-07-30 出版日期:2026-12-12 发布日期:2026-11-17
  • 通讯作者: 王金鑫 E-mail:383949535@qq.com

DIAGNOSIS AND TREATMENT OF MICROBIAL CONTAMINATION IN REVERSE OSMOSIS SYSTEM OF REFINING AND CHEMICAL WASTEWATER PLANT

  • Received:2026-06-15 Revised:2026-07-30 Online:2026-12-12 Published:2026-11-17

摘要: 以某炼化企业反渗透系统为研究对象,结合现场运行数据、膜表面污染物特征,系统诊断污染成因并提出综合处理方案。通过膜组件拆解、X射线能谱元素分析及傅里叶变换红外光谱表征,证实污染物主要为蛋白质、多糖类物质,符合微生物污染特征。针对微生物污染,研究采用“杀菌-碱洗-大流量冲洗-酸洗”组合化学清洗方案,有效剥离生物黏泥、疏通膜孔。经分析发现,非氧化性杀菌剂与还原剂同步投加致药剂失活为微生物滋生的根本原因,为此通过优化杀菌剂投加点位置、不同药剂错峰投加、强化进水余氯与氧化还原电位双参数管控,有效延缓了微生物污堵,可为炼化行业反渗透系统生物污染防控提供工程参考。

关键词: 炼化废水, 反渗透膜, 微生物污染, 化学清洗, 污水回用

Abstract: This study focuses on the reverse osmosis(RO)system in a refining and chemical enterprise. Pollution causes were diagnosed systematically by on-site operational data and themembrane surface contaminantscharacteristic, and a comprehensive treatment strategy was proposed accordingly. The main contaminant was confirmed to be proteins and polysaccharides, consistent with microbial contamination characteristics, as evidenced by the results of energy dispersive spectroscopy (EDS) elemental analysis and Fourier transform infrared spectroscopy (FTIR) . To address microbial pollution,a combined chemical cleaning processwas proposed including"bactericidal treatment, alkali washing, high-flow flushing, and acid washing" ,to effectively remove biological slime and uncloging membrane pores. It indicated that the simultaneous dosing of non-oxidizing biocides and reducing agents resulted in biocide deactivation.Itwas constituted the primary cause of excessive microbial reproduction. Consequently, through measures such as optimizing the biocide dosing point , staggering the dosing times and enhancing the dual-parameter control of influent residual chlorine and oxidation-reduction potential (ORP),the microbial fouling and blockage of the system was delayed effectively. This provides valuable engineering insights for the preventing and controlling biological pollution in RO systems in the refining and chemical industry.

Key words: refinery wastewater, reverse osmosis membrane, microbial contamination, chemical cleaning, wastewater reuse