石油炼制与化工 ›› 2026, Vol. 57 ›› Issue (3): 140-144.

• 节能减排 • 上一篇    下一篇

芳烃联合装置低温热发汽提质综合利用与节能优化

王天宇1,娄永峰2,孙龙祥2,高春杰2   

  1. 1. 中海油惠州石化有限公司
    2. 北京欧谊德科技有限公司
  • 收稿日期:2025-08-11 修回日期:2025-09-12 出版日期:2026-03-12 发布日期:2026-03-02
  • 通讯作者: 娄永峰 E-mail:cdlyf2008@126.com

COMPREHENSIVE UTILIZATION AND ENERGY-SAVING OPTIMIZATION OF LOW-TEMPERATURE HEAT FOR STEAM GENERATION AND UPGRADING IN AROMATICS COPLEX UNIT

  • Received:2025-08-11 Revised:2025-09-12 Online:2026-03-12 Published:2026-03-02

摘要: 针对芳烃联合装置低温热被冷却浪费的问题,为了实现装置节能减排,通过新增蒸汽发生器和蒸汽增压机,利用芳烃联合装置甲苯塔塔顶低温余热发生0.6 MPa蒸汽,并通过增压机提温增压至1.8 MPa,实现了低温余热综合利用和装置节能减排。进一步,系统分析了蒸汽发生器和增压机组的运行指标要求、操作参数和节能减排效果,并针对运行中的问题进行了优化。结果显示,该利用低温余热发生蒸汽项目设备运行稳定,均满足指标设计值要求;1.8 MPa蒸汽产量为25.57 t/h,可实现节能16150.5 tCE/a(1 kgCE=29.3 MJ),减少CO2排放量40263.2 t/a,经济和社会效益显著。

关键词: 芳烃联合装置, 甲苯塔, 低温余热, 发生蒸汽, 提质, 节能减排

Abstract: To address the issue of low-temperature heat being wasted in cooling within aromatics complex units, a steam generator and steam booster were added to utilize the low-temperature waste heat from the toluene column overhead. This system generates 0.6 MPa steam, which is then boosted to 1.8 MPa, achieving comprehensive utilization of low-temperature waste heat and energy-saving and emission-reduction goals in the unit. The operational requirements, operating parameters, and energy-saving and emission-reduction effects of the steam generator and booster unit were systematically analyzed, and optimizations were made for operational issues. The results show that the equipment in this low-temperature waste heat steam generation project operates stably and meets all design specifications. The 1.8 MPa steam produced reaches a flow rate of 25.57 t/h, enabling energy savings of 16150.5 tCE/a (1 kgCE = 29.3 MJ) and a reduction in CO2 emissions of 40263.2 t/a. The economic and social benefits are significant.

Key words: aromatics complex unit, toluene column, low-temperature heat, steam generation, quality upgrading, energy conservation and emission reduction