摘要: 城市型天然气脱硫站在实际运行中会产生气体流动噪声、机械振动噪声及工艺操作噪声等多种噪声污染,极易干扰周围居民生活。结合城市型天然气脱硫站噪声产生原因及传播特征,通过系统调研识别出站内高噪声设备设施为循环冷却水塔、泵组、空气分离装置、高速管道,噪声呈现宽频带和低中高频复合叠加的特性,噪声最大达96 dB(A)。通过对比不同噪声识别与治理技术,提出“声源优化控制-吸声减噪处理-隔声屏障阻隔”的综合治理方案,采取增设吸隔声屏障、设备隔声罩和消声器、管道包裹降噪等措施。治理方案实施后厂界等效声级均值可控制在47 dB(A)以下,优于《工业企业厂界环境噪声排放标准》(GB12348—2008)二级声环境功能区噪声标准要求,主要高噪声设备、设施的噪声平均降低19.6 dB(A)。

关键词: 噪声治理, 天然气脱硫站, 包裹降噪, 声源控制, 吸隔声屏障, 声阵列技术, 噪声频谱

Abstract: During actual operation, urban natural gas desulfurization stations generate various types of noise pollution, including gas flow noise, mechanical vibration noise, and process operation noise, which can easily disrupt the lives of surrounding residents. Based on an analysis of the noise generation causes and propagation characteristics in these stations, a systematic investigation has identified high-noise equipment and facilities within the stations, such as circulating cooling water towers, pump sets, air separation units, and high-speed pipelines. The noise exhibits characteristics of a wide frequency band and a composite superposition of low, medium, and high frequencies, with a maximum noise level reaching 96 dB(A). By comparing different noise identification and control technologies, a comprehensive noise control plan has been proposed, encompassing "source optimization control, sound absorption and noise reduction treatment, and sound barrier isolation." This plan involves measures such as installing additional sound absorption and insulation barriers, equipping devices with soundproof enclosures and silencers, and wrapping pipelines for noise reduction. After the implementation of this control plan, the average equivalent sound level at the plant boundary can be maintained below 47 dB(A), which is superior to the noise standard requirements for Class II sound environment functional areas specified in the "Emission Standard for Industrial Enterprise Boundary Environmental Noise" (GB12348—2008). The average noise reduction for the main high-noise equipment and facilities is 19.6 dB(A).

Key words: noise control, natural gas desulfurization station, wrapping noise reduction, noise source control, sound absorption and insulation barrier, acoustic array technology, noise spectrum